List 3: Test Probe and Endstop Inputs
1
Initial Limits Check
- Ensure no short between signal and ground
- Open WEBUI command line
- Enter command:
$limits - Status should scroll without trigger indications
2
Trigger Test with Jumper
💡
Use jumper cap to short signal and ground (refer to diagram)
- ⚠️ DO NOT short incorrect pins
- All switches and endstops should show triggered state
- Corresponding motherboard LED should illuminate
3
Jumper Removal
- Remove the jumper cap used for shorting
- System should return to normal un-triggered state
Expected Results
- Initial $limits command shows scrolling status without triggers
- When shorted: All endstops show triggered state and LEDs illuminate
- After jumper removal: System returns to normal un-triggered state