Table of Contents
List 9: Test xyzabc Axis Outputs
1
Initial Power-up
- Load test configuration YAML file
- Apply power to the system
- All 6 axis ENABLE signal indicator LEDs should illuminate
2
Axis Signal Indicator Testing
- Open WEBUI manual control interface
- Test X, Y, Z, A, B, C axes individually
- Test both forward and reverse directions for each axis
- Observe corresponding signal indicator LEDs for:
EN(Enable)DIR(Direction)CLK(Clock)GND(Ground)- LED changes indicate normal signal output
Expected Results
- All 6 axis ENABLE signal indicator LEDs illuminate on power-up
- Each axis responds to manual forward/reverse commands
- Corresponding signal indicator LEDs show activity
- All XYZABC axes demonstrate proper signal output
- No motor connection required for this verification